Skip to main content
  • 100V

153-6PL10 - Interface modules | Fieldbus slave modules with I/Os, DIO

Order no.

153-6PL10

TypeSM 153, PB-DP slave

General information

Note-
Features24x DI, DC 24 V
8x DO, DC 24 V, 1 A

Technical data power supply

Power supply (rated value)DC 24 V
Power supply (permitted range)DC 20.4...28.8 V
Reverse polarity protection
Current consumption (no-load operation)-
Current consumption (rated value)55 mA

Technical data digital inputs

Number of inputs24
Cable length, shielded1000 m
Cable length, unshielded600 m
Rated load voltageDC 24 V
Reverse polarity protection of rated load voltage-
Current consumption from load voltage L+ (without load)-
Rated valueDC 24 V
Input voltage for signal "0"DC 0...5 V
Input voltage for signal "1"DC 15...28.8 V
Input voltage hysteresis-
Frequency range-
Input resistance-
Input current for signal "1"7 mA
Connection of Two-Wire-BEROs possible
Max. permissible BERO quiescent current1.5 mA
Input delay of "0" to "1"3 ms
Input delay of "1" to "0"3 ms
Number of simultaneously utilizable inputs horizontal configuration24
Number of simultaneously utilizable inputs vertical configuration24
Input characteristic curveIEC 61131-2, type 1
Initial data size3 Byte

Technical data digital outputs

Number of outputs8
Cable length, shielded1000 m
Cable length, unshielded600 m
Rated load voltageDC 24 V
Reverse polarity protection of rated load voltage-
Current consumption from load voltage L+ (without load)50 mA
Total current per group, horizontal configuration, 40°C4 A
Total current per group, horizontal configuration, 60°C2 A
Total current per group, vertical configuration2 A
Output voltage signal "1" at min. currentL+ (-0.8 V)
Output voltage signal "1" at max. currentL+ (-1.5 V)
Output current at signal "1", rated value1 A
Output delay of "0" to "1"150 µs
Output delay of "1" to "0"100 µs
Minimum load current-
Lamp load5 W
Parallel switching of outputs for redundant control of a loadnot possible
Parallel switching of outputs for increased powernot possible
Actuation of digital input
Switching frequency with resistive loadmax. 1000 Hz
Switching frequency with inductive loadmax. 0.5 Hz
Switching frequency on lamp loadmax. 10 Hz
Internal limitation of inductive shut-off voltageL+ (-52 V)
Short-circuit protection of outputyes, electronic
Trigger level1.5 A
Number of operating cycle of relay outputs-
Switching capacity of contacts-
Output data size1 Byte

Status information, alarms, diagnostics

Status displaygreen LED per channel
Interruptsno
Process alarmno
Diagnostic interruptno
Diagnostic functionsno
Diagnostics information read-outpossible
Supply voltage displayyes
Group error displayred SF LED
Channel error displaynone

Isolation

Between channels-
Between channels of groups to-
Between channels and backplane bus-
Between channels and power supply-
Max. potential difference between circuits-
Max. potential difference between inputs (Ucm)-
Max. potential difference between Mana and Mintern (Uiso)-
Max. potential difference between inputs and Mana (Ucm)-
Max. potential difference between inputs and Mintern (Uiso)-
Max. potential difference between Mintern and outputs-
Insulation tested withDC 500 V

Hardware configuration

Racks, max.-
Modules per rack, max.-
Number of digital modules, max.-
Number of analog modules, max.-

Communication

FieldbusPROFIBUS-DP to EN 50170
Type of interfaceRS485
ConnectorSub-D, 9-pin, female
TopologyLinear bus with bus termination at both ends
Electrically isolated
Number of participants, max.125
Node addresses1 - 99
Transmission speed, min.9.6 kbit/s
Transmission speed, max.12 Mbit/s
Address range inputs, max.3 Byte
Address range outputs, max.1 Byte
Number of TxPDOs, max.-
Number of RxPDOs, max.-

Datasizes

Input bytes3
Output bytes1
Parameter bytes7 + 5
Diagnostic bytes13

Housing

MaterialPPE / PA 6.6
MountingProfile rail 35 mm

Mechanical data

Dimensions (WxHxD)152.4 mm x 76 mm x 48 mm
Net weight264 g
Weight including accessories-
Gross weight-

Environmental conditions

Operating temperature0 °C to 60 °C
Storage temperature-25 °C to 70 °C

Certifications

UL certificationyes
KC certification-

Downloads

[Datasheet]
[Manual]